Inclined plate settlers inside a Lamella Clarifier are positioned on a 55-60° angle to allow the settled solids to slide down the plate and to the bottom of lamella clarifier. In this case the distance the particle must travel vertically is:
D= Distance the Particle Travels Vertically
d= Plate Spacing
Cos µ = Cosine of Plate Angle (55-60°)
Cos µ=d/D
D=d/Cos µ
Inclined plate settlers use the horizontally projected area and, therefore, the total plate area may be calculated by:
S1=S2*Cosµ
S2 = S1/Cosµ
S1 = Horizontally Projected Area
Cos µ = Cosine of Plate Angle (55-60°)
S2 = Total Area of Plate Surface Required
Because each plate settler provides an effective settling area equal to that of its horizontal projection, Lamella Plate Settlers will increase a lamella clarifier's effective settling area by up to ten times. For the details and standard specification of Lamella Clarifier, please click to read: Standard Lamella Clarifier.
Contact: Eng. Dover
Mobile: +86 17561675721
Whatsapp: +86 17561675721
QQ: 1049235017
Wechat: 1049235017
Email: dover@cnwwtp.com
Addr: Beiling, Machang Vil.
City: Qingdao, China.